Engine Output Format#
Suffix Settings#
PL5 does not have a dedicated “Suffix Settings” chapter. In the wireless customized version, keep the minimum suffix workflow: first set Scan Suffix 1 or Scan Suffix 2, then write Prefix/Suffix Values, and finally select a Scan Data Transmission Format that includes the suffix.
Common terminator values:
1013:CR/ Enter.7013:Enter, commonly used in terminal orFN1substitution value scenarios.
Recommended procedure:
Scan
Scan Suffix 1orScan Suffix 2.Use numeric setting barcodes to enter
1013or7013.Scan for
<DATA> <SUFFIX 1>,<DATA> <SUFFIX 2>or<DATA> <SUFFIX 1> <SUFFIX 2>.To cancel suffix output, scan
Data As Is.
Scan suffix 1#
Scan suffix 2#
\* Data As Is#
<DATA> <SUFFIX 1>#
<DATA> <SUFFIX 2>#
<DATA> <SUFFIX 1> <SUFFIX 2>#
<PREFIX> <DATA> <SUFFIX 1>#
<PREFIX> <DATA> <SUFFIX 2>#
<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2>#