System Settings#
Input/output settings#
Introduction#
This chapter mainly introduces the configuration of the buzzer and LED when the code reading device is powered on, decoded, and button triggered.
Power on beeper setting#
Power-on prompt sound, that is, after the code reading device is successfully powered on, it can sound a buzzer to prompt it to enter the working state. According to the needs of the scene, it can also be configured to have no prompt sound. Default value = there will be a prompt sound when power on successfully.
No beep after successful power-on#
* There will be a beeper after successful power-on.#
Trigger decoding sound settings#
After triggering the decoding switch, regardless of whether it is decoded or not, the code reading device can emit a tone to indicate that the switch has been triggered. Default value = no beep when triggering decoding switch
* No beep when triggering decoding switch#
There is a sound when triggering the decoding switch.#
Setting the beeper after successful decoding#
Decoding success beeper response setting#
After the decoding is successful, the buzzer will sound to indicate that the decoding is successful. If a prompt sound is not required, it can be configured to have no prompt sound after the decoding is successful. Default value = prompt sound after successful decoding.
No beep after successful decoding#
* There will be a prompt sound after successful decoding.#
Decoding success sound volume setting#
Scan the following barcode to modify the beep volume of the code reading device after successful decoding. Default = high.
Low#
Medium#
* High#
Disable#
Decoding success beeper frequency setting#
Scan the following barcode to modify the beep frequency of the code reading device after successful decoding. The default value is medium.
* Medium (2400 Hz)#
Low (1600 Hz)#
High (4200 Hz)#
Decoding success prompt sound duration setting#
Scan the following barcode to modify the beep duration of the code reading device after successful decoding. Default=Normal.
*Normal beep#
short beep#
Decoding failure beeper frequency setting#
Scan the following barcode to modify the beep frequency of the code reading device after decoding failure. Default=Razz.
\* Razz (250 Hz)#
Medium (3250 Hz)#
High (4200 Hz)#
code reading delay#
Scan the following barcode to set the time interval between the barcode reading device reading one barcode and then reading the next barcode. Default=750 ms.
No delay#
* Short delay (750 ms)#
Medium latency (1,000 ms)#
Long delay (1,500 ms)#
Common functions#
Factory Default Settings#
If you want to apply default settings to your code reading device, scan the “Load Factory Default Settings” barcode below to reset your code reading device to factory default settings.
Load factory default settings#
Firmware version display#
Scanning the following barcode will output the current firmware version, unit serial number and other product information.
Show version information#